PAUSE_INPUT_ENABLE
Value Format BOOLEAN
Description Specifies whether to enable or disable pause input.
Value Range
• Y: Enable
• N: Disable
Default Value
N
NUM_PLAN_PICKUP_DIRECT
Value Format STRING
Description Specifies the feature number assigned to a BLF for performing call
pickup.
Value Range 0–4 digits (0–9, *, #)
Default Value Empty string
Web User Interface Reference Directed Call Pickup (Page 122)
5.3.27 Flexible Button Settings
FLEX_BUTTON_FACILITY_ACTx
Parameter Name Example FLEX_BUTTON_FACILITY_ACT1, FLEX_BUTTON_FACILITY_ACT2
Value Format STRING
Description x=1–2
Specifies a particular Facility Action for the flexible button. No facility
action will be taken for the button if the string is empty or invalid.
Note
• If this parameter is specified,
"FLEX_BUTTON_QUICK_DIALx" should be an empty string.
Value Range X_PANASONIC_IPTEL_ONETOUCH,
X_PANASONIC_IPTEL_BLF
Default Value Empty string
Web User Interface Reference Type (Page 130)
FLEX_BUTTON_FACILITY_ARGx
Parameter Name Example FLEX_BUTTON_FACILITY_ARG1, FLEX_BUTTON_FACILITY_ARG2
Value Format STRING
Document Version 2015-02 Administrator Guide 243
5.3.27 Flexible Button Settings