Value Range 0–16000 (msec) (0=Continuous)
Note
• Avoid setting 1–50 for any of the values.
Default Value 60,0
Web User Interface Reference Tone Timings (Page 131)
DIAL_TONE2_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of Dial Tone 2 using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 350,440
DIAL_TONE2_GAIN
Value Format INTEGER
Description Specifies the gain, in decibels, of Dial Tone 2.
Value Range -24–6 (dB)
Default Value 0
DIAL_TONE2_RPT
Value Format INTEGER
Description Specifies whether Dial Tone 2 is repeated.
Value Range 0–1
• 0: No Repeat
• 1: Repeat
Default Value 0
DIAL_TONE2_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of Dial Tone 2 using up to 10
whole numbers
(off 1, on 1, off 2, on 2…) separated by commas.
Note
• It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Document Version 2015-02 Administrator Guide 247
5.3.28 Tone Settings