BUSY_TONE_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers
(off 1, on 1, off 2, on 2…) separated by commas.
Note
• It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Continuous)
Note
• Avoid setting 1–50 for any of the values.
Default Value 60,500,440
Web User Interface Reference Tone Timings (Page 132)
REORDER_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of reorder tones using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 480,620
Web User Interface Reference Tone Frequencies (Page 133)
REORDER_TONE_GAIN
Value Format INTEGER
Description Specifies the gain, in decibels, of the reorder tone.
Value Range -24–6 (dB)
Default Value 0
REORDER_TONE_RPT
Value Format INTEGER
Description Specifies whether the reorder tone is repeated.
Value Range 0–1
– 0: No Repeat
– 1: Repeat
Default Value 1
250 Administrator Guide Document Version 2015-02
5.3.28 Tone Settings