Value Range Max. 384 characters
Note
• If this URL ends with "/" (slash), "{MODEL}.cfg" is
automatically added at the end of the URL. For example,
CFG_PRODUCT_FILE_PATH="http://host/ dir/" becomes
CFG_PRODUCT_FILE_PATH="http:// host/dir/{MODEL}.cfg".
• For details about the formats, see 2.1.3 Server Address
Formats.
Default Value Empty string
Web User Interface Reference Product File URL
CFG_MASTER_FILE_PATH
Value Format STRING
Description Specifies the URL of the master configuration file, which is used
when all units need the same settings.
Value Range Max. 384 characters
Note
• If this URL ends with "/" (slash), "sip.cfg" is automatically
added at the end of the URL. For example,
CFG_MASTER_FILE_PATH="http://host/ dir/" becomes
CFG_MASTER_FILE_PATH="http:// host/dir/sip.cfg".
• For details about the formats, see 2.1.3 Server Address
Formats.
Default Value Empty string
Web User Interface Reference Master File URL
CFG_CYCLIC
Value Format BOOLEAN
Description Specifies whether the unit periodically checks for updates of
configuration files.
Value Range
• Y: Enable periodic synchronization
• N: Disable
Default Value
N
Web User Interface Reference Cyclic Auto Resync
CFG_CYCLIC_INTVL
Value Format INTEGER
Description Specifies the interval, in minutes, between periodic checks for
updates of the configuration files.
Value Range 1–40320
Default Value 10080
5.3.5 Provisioning Settings
Document Version: 2017-07 Administrator Guide 217