Description Specifies, in minutes, a time range during which connected units can
access the server. Units will download the firmware file at a random
time within this range.
Value Range 0–1439
Default Value 0
5.3.7 HTTP Settings
HTTP_VER
Value Format INTEGER
Description Specifies which version of the HTTP protocol to use for HTTP
communication.
Value Range
• 1: Use HTTP/1.0
• 0: Use HTTP/1.1
Note
• For this unit, it is strongly recommended that you specify "1" for
this setting. However, if the HTTP server does not function well
with HTTP/1.0, try changing the setting "0".
Default Value 1
Web User Interface Reference HTTP Version
HTTP_USER_AGENT
Value Format STRING
Description Specifies the text string to send as the user agent in the header of
HTTP requests.
Value Range Max. 64 characters
Note
• If "{mac}" is included in this parameter, it will be replaced with
the unit’s MAC address in lower-case.
• If "{MAC}" is included in this parameter, it will be replaced with
the unit’s MAC address in upper-case.
• If "{MODEL}" is included in this parameter, it will be replaced
with the unit’s model name.
• If "{fwver}" is included in this parameter, it will be replaced with
the firmware version of the unit.
Default Value Panasonic_{MODEL}/{fwver} ({mac})
Web User Interface Reference HTTP User Agent
HTTP_AUTH_ID
Value Format STRING
Description Specifies the authentication ID required to access the HTTP server.
5.3.7 HTTP Settings
Document Version: 2017-07 Administrator Guide 223