Description Specifies the default interval, in milliseconds, between transmissions
of SIP messages. For details, refer to RFC 3261.
Value Range
250
500
1000
2000
4000
Default Value 500
Web User Interface Reference T1 Timer
SIP_TIMER_T2_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format INTEGER
Description Specifies the maximum interval, in seconds, between transmissions
of SIP messages. For details, refer to RFC 3261.
Value Range
2
4
8
16
32
Default Value 4
Web User Interface Reference T2 Timer
SIP_TIMER_T4_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format INTEGER
Description Specifies the maximum period, in seconds, that a message can
remain on the network.
Value Range
0
1
2
3
4
5
Default Value 5
SIP_TIMER_B_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format INTEGER
5.3.22 SIP Settings