CODEC_ENABLEx_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format BOOLEAN
Description Specifies whether to enable the codec specified in the parameter list.
Note
• The "x" character in the parameter title should be changed to
one of the following numbers, according to the codec to be
changed.
– 0: G.722
– 1: PCMA
– 3: G.729A
– 4: PCMU
• For codec setting examples, see 2.5.1 Examples of Codec
Settings.
Value Range
• Y: Enable
• N: Disable
Default Value
Y
Web User Interface Reference
• G.722 Enable
• PCMA Enable
• G.729A Enable
• PCMU Enable
CODEC_PRIORITYx_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format INTEGER
Description Specifies the priority order for the codec.
Note
• The "x" character in the parameter title should be changed to
one of the following numbers, according to the codec to be
changed.
– 0: G.722
– 1: PCMA
– 3: G.729A
– 4: PCMU
• For codec setting examples, see 2.5.1 Examples of Codec
Settings.
Value Range 1–255
Default Value 1
5.3.24 CODEC Settings
294 Administrator Guide Document Version: 2017-07