SIP_TIMER_H_n
Parameter Name Example SIP_TIMER_H_1, SIP_TIMER_H_2
Value Format INTEGER
Description Specifies the value of SIP timer H (wait time for ACK reception), in
milliseconds. For details, refer to RFC 3261.
Value Range 250–64000
Default Value 32000
SIP_TIMER_J_n
Parameter Name Example SIP_TIMER_J_1, SIP_TIMER_J_2
Value Format INTEGER
Description Specifies the value of SIP timer J (wait time for non-INVITE request
resending), in milliseconds. For details, refer to RFC 3261.
Value Range 0, 250–64000
Default Value 5000
SIP_100REL_ENABLE_n
Parameter Name Example SIP_100REL_ENABLE_1, SIP_100REL_ENABLE_2
Value Format BOOLEAN
Description Specifies whether to add the option tag 100rel to the
"Supported"
header of the INVITE message. For details, refer to RFC 3262.
Value Range
Y (Enable 100rel function)
N (Disable 100rel function)
Note
If set to "Y", the Reliability of Provisional Responses function
will be enabled. The option tag 100rel will be added to the
"Supported" header of the INVITE message and to the
"Require" header of the "1xx" provisional message.
If set to "N
", the option tag 100rel will not be used.
Default Value
Y
Web User Interface Reference Enable 100rel (RFC 3262) (Page 125)
SIP_18X_RTX_INTVL_n
Parameter Name Example SIP_18X_RTX_INTVL_1, SIP_18X_RTX_INTVL
_2
Value Format INTEGER
246 Administrator Guide Document Version 2015-12