5.3.7 HTTP Settings
HTTP_VER
Value Format INTEGER
Description Specifies which version of the HTTP protocol to use for HTTP
communication.
Value Range
• 1 (Use HTTP 1.0)
• 0 (Use HTTP 1.1)
Note
• For this unit, it is strongly recommended that you specify "1" for
this setting. However, if the HTTP server does not function well
with HTTP 1.0, try changing the setting "0".
Default Value 1
Web User Interface Reference HTTP Version
HTTP_USER_AGENT
Value Format STRING
Description Specifies the text string to send as the user agent in the header of
HTTP requests.
Value Range Max. 64 characters
Note
• If "{mac}" is included in this parameter, it will be replaced with
the unit’s MAC address in lower-case.
• If "{MAC}" is included in this parameter, it will be replaced with
the unit’s MAC address in upper-case.
• If "{MODEL}" is included in this parameter, it will be replaced
with the unit’s model name.
• If "{fwver}" is included in this parameter, it will be replaced with
the firmware version of the unit.
Default Value Panasonic_{MODEL}/{fwver} ({mac})
Web User Interface Reference HTTP User Agent
HTTP_AUTH_ID
Value Format STRING
Description Specifies the authentication ID required to access the HTTP server.
Value Range Max. 128 characters
Default Value Empty string
Web User Interface Reference Authentication ID
5.3.7 HTTP Settings
Document Version 2016-05 Administrator Guide 187