Weight (when fully mounted) Under 2.2 kg (4.9 lb)
Installation Environment Wallmount
Horizontal (Desktop) installation
2.3.2 Characteristics
Terminal Equipment Loop Limit
• SLT: 600 Ω including set
• Doorphone: 20 Ω
Minimum Leakage Resistance 15 000 Ω minimum
Maximum Number of Extension
Instruments per Line
1 for SLT
Ring Voltage 65 Vrms at 20 Hz/25 Hz depending on the Ringing Load
For Malaysia, 75 Vrms
Trunk Loop Limit 1600 Ω maximum
Hookswitch Flash/Recall Timing
Range
24 ms to 2032 ms
2.3.3 System Capacity
System Capacity
Items Default
Maximum
Number
Remarks
Total Trunk (Channel/Port) - 8
*1
SIP Trunk (Channel)
[Without G729 settings]
*2
6 6
SIP Trunk (Channel)
[With G729 settings]
*3
4 4
Analog Trunk (Port)
[Without G729 settings]
*2
4 8 1 LCOT4 option card is required
Analog Trunk (Port)
[With G729 settings]
*3
4 6 1 LCOT4 option card is required
Total Extension (Channel/Port) - 24
SIP Extension (Channel)
[G711/G722]
24
Includes softphone for smartphone or
Personal Computer. Allows setting of
Remote extension for each SIP
extension. Remote extension can be
set up to 8 lines.
Analog Extension (Port) 8 24 2 SLC8 option cards are required
Doorphone 0 2 1 DPH2 option card is required
Wireless LAN access point 1
DISA/AA/VM channel 4
*1
When Codec used by the SIP Trunk consists of G711 only, the maximum number of combinations of the Analog Trunk port
number and SIP Trunk port number is as follows:
2.3.2 Characteristics