12.3.5.3. CALL SERVICE 3
"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC300-C21.
* When Call Service 3 occurred, the cause can be distinguished by service mode 655.
•*Service mode *655 tells the detection number and 3 latest temperatures of the thermistor. The detection point of the Call Ser-
vice 3 and the thermistor temperature is displayed. Maximum 3 latest temperatures are displayed showing the newest on the
left. [AABB CCDD EEFF] AA, CC and EE show the detection points and BB, DD and FF show their temperature detection
points.
00: CALL SERVICE 3 did not occur.
01: means that the value of AD did not increased by 4 steps or more within 10sec soon after the heater was turned ON.
(thermistor’s open detection)
02: means that it did not reach the first stabilizing temperature (170°C: 73h) within 50 seconds.
03: means that it did not reach the second stabilizing temperature (195°C: 59h)* within 75 seconds after reaching the first
stabilizing temperature (170°C: 73h).
04: means that it dropped to -60 deg or below by the temperature control after reaching the second stabilizing temperature
(195°C: 59h)*.
05: means that it did not reach the first stabilizing temperature (170°C: 73h) within 35 seconds from detection temperature 1
(70°C: E2h).
06: means that it became 235°C: 39h or over during printing.
07: means that during printing the short of the thermistor (AD: 00h) was detected.
08: means that the thermistor’s short (AD: 00h) were detected.
09: means that it became 235°C: 39h or over during sleep condition (heater OFF).
*: depend on its printing conditions (room temperature, number of printing, printing paper size etc.).
Note:
Refer to Heat Lamp Control Circuit (P.86) for technical description.