23.3.5 UM Configuration—[4-3] Service Settings—Custom
Service—Password
The below parameters are set for the Password Custom Service in the Custom Service Builder.
This
service requires that callers enter a password, followed by "#". Each password is assigned an operation.
If a password is entered correctly, the caller is handled by the password’s pre-programmed operation. The
prompt for this service can be recorded in the CS No. dialog box.
Custom Service prompts can be recorded only in On-line mode.
Description
The information typed in this field is for reference only.
Default
Not stored
Value Range
Max. 32 characters
Maintenance Console Location
23.3.5 UM Configuration
—[4-3] Service Settings—Custom Service—Password
Feature Manual References
20.1.27 Unified Messaging—Custom Service
Menu Repeat Cycle (1-3)
Specifies the number of times the Custom Service menu message will be repeated to the caller.
Default
1
Value Range
1–3 times
Maintenance Console Location
23.3.5 UM Configuration
—[4-3] Service Settings—Custom Service—Password
Feature Manual References
20.1.27 Unified Messaging—Custom Service
Wait for First Digit (0-10 s)
Specifies
the length of time that the system waits for the caller to dial the first digit after a Custom Service menu
is played for the caller. If this time expires, the No DTMF Operation setting determines how the call is then
handled.
Document Version 2016-03 PC Programming Manual 1031
23.3.5 UM Configuration—[4-3] Service Settings—Custom Service—Password