Feature Manual References
20.1.84 Unified Messaging—System Security
Password for Message Manager (Message Client)
Specifies the password for the Message Manager for accessing the Unified Messaging system from the
messaging client.
Default
Not stored
Value Range
4–16 characters (A–Z, a–z, 1–9)
Maintenance Console Location
26.1 UM Configuration
—[7] System Security—Manager
Feature Manual References
20.1.84 Unified Messaging—System Security
Subscriber
Minimum Password Length (0-16 digits)
Specifies the minimum length (number of digits) of mailbox passwords.
Default
4
Value Range
0–16
Maintenance Console Location
26.1 UM Configuration—[7] System Security—Subscriber
Enable Login Failure Disconnection
Specifies whether the system disconnects a call when the subscriber enters an invalid password n times.
(n=the value specified under Login Failures before Disconnection (1-99 times))
Default
Enable
Value Range
Disable, Enable
Maintenance Console Location
26.1 UM Configuration
—[7] System Security—Subscriber
1086 PC Programming Manual Document Version 2016-03
26.1 UM Configuration—[7] System Security

Table of Contents

Other manuals for Panasonic KX-NS1000