4.1.2 Status—Equipment Status—CS Information
Displays information stored by the PBX regarding each Cell Station
(CS).
This option is only available for the Installer level account in On-line mode, and requires that the target
V-IPCS4 card be set to INS status.
The displayed items are as follows:
Item Description
Site Number of the site
Shelf Number of the shelf
Slot Number of the slot
Port Number of the port
CS Name Name of the attached CS
Status Service status of the attached CS: INS, OUS, or FAULT.
If the status is FAULT, subsequent data items for that port will be left
blank.
Version Version number of the program file stored in the CS
Revision Revision number of the program file stored in the CS
CSID 12-digit ID number of the CS
Path Number of the wireless extension currently using each path. In the case
of
a group, several extensions may be using the same floating extension
number.
When an extension number is not registered, the display shows
"OFF". The number of paths that can be used varies for each CS model.
For more details, see the documentation for your CS.
Group Call Number of PSs registered to the attached CS that are members of a PS
Ring Group.
To view CS information
1. From the Target CS I/F Shelf-Slot No. drop-down list, select the target shelf and slot.
To display information on a single card, select the shelf number, slot number and name of that card.
To display information on all matching cards, select
"All".
2. From the Interval Timer drop-down list, select the number of seconds between each automatic screen
refresh.
3. If you want to save the CS information, click Capture.
a. Create a file for saving the data.
b. Click Start.
c. Click Close.
4. Click Start to begin monitoring.
Monitoring will be performed and the screen will refresh according to the interval specified.
5. Click Stop to end monitoring.
6. If you started to save the CS information in step 3, click Capture, then click Stop to record the information
to the specified file.
7. Click Close to return to the main screen.