4-14 System Programming
[100]-[101] 4.2 System Programming
Enables or disables automatically locating an idle extension in the same extension group as
the dialled extension, when the called extension is busy. If “Enable” is selected, assign the
next program [101] “Hunting Type”. Extension groups are defined in program [600]
“Extension Group Assignment”.
* Extension group number: 1 through 8 / (all extension groups)
Default All extension groups – Disable
• Feature Reference
Section 3, Features
Extension Hunting
Assigns the hunting type, Terminate or Circular, to each extension group when a hunting
group is enabled in program [100] “Hunting Group Set”.
* Extension group number: 1 through 8 / (all extension groups)
Default All extension groups – Terminate
• Feature Reference
Section 3, Features
Extension Hunting
(1···8/ )
[100] Hunting Group Set
(1···8/ )
[101] Hunting Type
(Enable/
Disable)
(Terminate/
Circular)
extension group no.*
extension group no.*
or
☞
☞
or
PSQX1708ZA-07E.QX 99.10.15 10:34 AM Page 14