4-54 System Programming
4.3.2 Extension Group
Parameter
Value Range
(default)
Description/Function Reference
Tenant
Sec. 4.2.1
Specifies a tenant number (1-8) to which the Extension
Group is assigned.
(Required if “Tenant Service” is employed.)
Specifies the destination extension where the call is
transferred to when all extensions in the Extension
Group are busy or logged-out in Day / Night mode
respectively.
Specifies the length of time in minutes the system is to
wait before transferring the call in the waiting queue to
the Overflow Destination.
Specifies whether to enable or disable the FWD / DND
(Call Forwarding or Do Not Disturb) feature assigned
on an extension in the Extension Group.
(Assignable only when “Group Type” is set to
“Terminate,” “ Circular” or “ UCD.”)
Specifies whether station hunting feature works or not
when the other party calls a busy extension in the group
by dialing DN of the extension (extension call).
[Note]
• When the other party calls the group by dialing the
FDN of the group, station hunting always works
regardless of this setting.
(Assignable only when “Group Type” is set to
“Terminate” or “Circular.”)
Specifies whether the calls coming in to an Operator
Group ring one Operator (Single) or all Operators in the
group (Multi) simultaneously.
(Assignable only when “ Operator” is specified in
“Group Type” programming.)
Specifies the answering priority of incoming calls to
the Extension Group by call type when more than one
call is ringing at an Operator extension.
(Assignable only when “ Operator” is specified in
“Group Type” programming.)
1 - 8
(1)
3 or 4 digits
consisting of 0-9
(None)
0 - 60 min
(0)
1. Disable
2. Enable
(Enable)
1. Enable
2. Disable
(Enable)
1. Multi
2. Single
(Multi)
Priority 1 - 4
(CO Call : 1
IRNA : 2
Recall : 3
Extension : 4)
Tenant No.
Overflow Setting
Destination
Timer
FWD/DND
Mode
Extension Call
Hunting
Operator Setting
Ringing Type
Call Priority
Day
Night