Utility 5-13
5.2.1 Card/Port Test (On-line diagnosis)
[PITS Path Test]
6. Click PITS Path Test .
• “PITS Path Test” screen is displayed.
7. Specify the port number to be tested, or select “All.”
• If you select “All,” all ports on the selected card will be tested at a time.
8. Click Execute .
After executing the test, the test result is displayed.
Example: When a DHLC card is installed in the Slot No. 103.
Description
Error Indication Table
*This message will also be displayed, if the test target card is an SLT card.
Item
Card
Port No.
Result
Error Indication
Display/Input Value
Card No. : Type
1-8/16/all
OK
NG
See “Error Indication
Table.”
Description
The card number and the type of the target card
to be diagnosed. (The card specified in “Card
Information” screen is displayed automatically.)
Used to specify the port number of the
extension card to be diagnosed.
The results of diagnosis.
The details of an error.
Displayed only when Result is NG (no good).
Error Message
PITS Link failure*
PITS PB Generator failure
Description
Communication link between the target card
and PITS is abnormal.
PITS PB Generator is not functioning
properly.