1.6 Specifications
1-20 System Outline
(3) Interface for diagnostic transfer (DT) by each port
The interface for diagnostic transfer is similar to the SLC
card.
(4) Interface for the SLT with Message Waiting Lamp.
Operation The LED indicator on the ESLC card lights when the system
resets or ESLC local reset occurs.
■ E&M Card (KX-T96184)
Functions E&M card
(1) E&M (Tie) Line Types......... Type 5 only.
(2) Transmission ........................ 2-wire or 4-wire voice path
(Programmable)
(Note) Maximum cabling distance of E&M line cord
(twisted cable):22 AWG: Under 9.6 km
(3) Transmission levels
2-wire voice path.................. -3 dB (transmit/receive)
4-wire voice path..................
-3 dB normal (transmit/receive)
Programmable (-6 dB, -3dB,
0dB, +3dB)
(4) Signaling DTMF or Pulse
(5) E lead Battery
-48 VDC, -20mA to ground (max.)
Sensitivity
5mA or 2000Ω to ground (max.)
(min.)
(6) M lead Permitted current : 30mA (max.)
Permitted voltage: ±100V (max.)
■ E-1 Digital Trunk Card (KX-T96188)
Functions E-1 interface. (1 circuit / card)
E-1 is a digital transmission link with a capacity of
2.048Mbps.
E-1 can carry 30 voice conversations.
Frame Format : PCM30/PCM30-CRC
Line Coding : AMI / HDB3
Channel Type : DR2 / E&M-C / E&M-P
Signaling : Pulse / DTMF / MFC-R2
Operation The LED indicator on E-1 card lights when the system
resets, or E-1 card local reset or E-1 line fault occurs.