2.5 Outside Line Programming
General Programming 169
2.5 Outside Line Programming
[400] Outside Line Connection Assignment
Description
Used to identify the outside lines which are connected to the system(s). This prevents users
from originating a call to a line which is not connected.
Selection
• Outside line (CO) number:
KX-TD816 –
01 through 08
,
KX-TD1232 –
01 through 54
,
( =all outside lines)
•
Connect / No Connect
Default
All outside lines – Connect
(If KX-TD290 or KX-TD188 is connected: All outside lines in the Slave System – No
Connect)
Programming
1.
Enter
400
.
Display: 400 CO CONNECT
2.
Press
NEXT
.
Display: CO Line NO?
3.
Enter an
outside line number
.
To enter outside line number 01, you can also press
NEXT
.
Display example: CO01:Connect
4.
Keep pressing
SELECT
until the desired selection is displayed.
5.
Press
STORE
.
6.
To programme another outside line, press
NEXT
or
PREV
, or
SELECT
and the desired
outside line number
.
7.
Repeat steps 4 through 6.
8.
Press
END
.
Conditions
• For the KX-TD1232, outside lines 01 through 12 are for the Master System and outside
lines 13 through 24 are for the Slave, if available.