2.5 Outside Line Programming
General Programming 179
[405] CPC Signal Detection Incoming Set
Description
Assigns the expected minimum duration of the Calling Party Control (CPC) Signal on
incoming outside calls. If this is programmed, the system disconnects the line when the CPC
Signal is detected.
Selection
• Outside line (CO) number:
KX-TD816 –
01 through 08,
KX-TD1232 –
01 through 24,
( =all outside lines)
• Time (milliseconds):
Disable
(no detection)
/ 100 / 200 / 300 / 400 / 500 / 600
Default
All outside lines – Disable
Programming
1.
Enter
405
.
Display: 405 CPC INCOMING
2.
Press
NEXT
.
Display: CO Line NO?
3.
Enter an
outside line number
.
To enter outside line number 01, you can also press
NEXT.
Display example: CO01:Disable
4.
Keep pressing
SELECT
until the desired selection is displayed.
5.
Press
STORE
.
6.
To programme another outside line, press
NEXT
or
PREV,
or
SELECT
and the desired
outside line number
.
7.
Repeat steps 4 through 6.
8.
Press
END
.
Conditions
• For the KX-TD1232, outside lines 01 through 12 are for the Master System and outside
lines 13 through 24 are for the Slave, if available.
• To assign all outside lines to one selection, press the key in step 3. In this case, the display
shows the contents programmed for outside line 01.
• You may disable CPC Signal Detection for an outside line.