3.3 ISDN Line Programming
ISDN Programming 315
[427] ISDN TEI Mode
Description
Assigns the Terminal Endpoint Identifier (TEI) mode on an ISDN port basis.
Selection
• Port number:
KX-TD816 –
01 through 06,
KX-TD1232 –
01 through 12,
( =all ports)
•
Fix 0 through 63 / Automatic
Default
KX-TD816: Port 05 and 06 – Automatic; Other ports – Fix 0
KX-TD1232: All ports – Fix 0
Programming
1.
Enter
427
.
Display: 427 TEI ASSIGN
2.
Press
NEXT.
Display: Port NO?
3.
Enter a
port number.
To enter port number 01, you can also press
NEXT.
Display example: #01:Fix 0
4.
Enter the
TEI.
To change the current entry, press
CLEAR
and enter the new number. If you do not enter
a number, "Automatic" is automatically assigned.
5.
Press
STORE.
6.
To programme another port, press
NEXT
or
PREV,
or
SELECT
and the desired
port
number.
7.
Repeat steps 4 through 6.
8.
Press
END.
Conditions
• For the KX-TD1232, port numbers 01 through 06 are for the Master System and 07 through
12 are for the Slave, if available.
• If "Point" is selected in programme [425], assign the fixed TEI. If "Multipoint" is selected,
assign "Automatic".