3.4 Extension Programming
330 ISDN Programming
[612] DDI Number / Floating Number Conversion
Description
Used to convert a Direct Dialling In (DDI) number to an floating number in order to place an
incoming DDI call at a specific floating station.
Selection
• Floating Station:
Operator / Pager 1 / Pager 2 / Pager 3 / Pager 4 / DISA 1 / DISA 2 / MODEM / EXT
Group 1 / EXT Group 2 / EXT Group 3 / EXT Group 4 / EXT Group 5 / EXT Group
6 / EXT Group 7 / EXT Group 8
(Pager 2 through 4 are available for the KX-TD1232 only.)
• DDI Number:
6 digits (max.)
Default
All floating stations – Blank
Programming
1.
Enter
612
.
Display: 612 FLOAT DDI #
2.
Press
NEXT
to programme the operator.
Display: Operator:
3.
Enter a
DDI number
.
To delete the current entry, press
CLEAR
.
4.
Press
STORE
.
5.
To programme another floating station, press
NEXT
or
PREV
until the desired floating
station is displayed.
6.
Repeat steps 3 through 5.
7.
Press
END
.
Conditions
• Each DDI number can be a maximum of six digits, consisting of
0 through 9
.
• To use this programme, "DDI conversion number" must be selected in programme
[990] System Additional Information, Area 06 - bit 13.
Features Guide References
Direct Dialling In (DDI)