4.4 E1 Line Programming
E1 Programming 353
[722] E1 Answer Wait Timer
Description
Assigns an automatic disconnect timer to stop making a call on E1 line, if the called party does
not answer.
This programme is available for the KX-TD1232 only.
Selection
• Outside (CO) line number:
25 through 54,
( = all outside lines from 25 to 54)
• Time (minutes):
0 / 1 / 2 / 3 / 4
(0=no disconnection)
Default
All outside lines – 1 min
Programming
1.
Enter
722
.
Display: 722 ANSWER WAIT
2.
Press
NEXT
.
Display: CO Line NO?
3.
Enter an
outside line number
.
To enter an outside line number 25, you can also press
NEXT
.
Display example: CO Line NO? 25
4.
Press
NEXT
.
Display example: CO25:1min
5.
Keep pressing
SELECT
until the desired selection is displayed.
6.
Press
STORE
.
7.
To programme another outside line, press
NEXT
or
PREV
, or
SELECT
and the desired
outside line number
.
8.
Repeat steps 4 through 7.
9.
Press
END
.
Conditions
None
Features Guide References
E1 Line Service