2.2 System Programming
60 General Programming
[103] Automatic Access Outside Line Group Assignment
Description
Assigns the sequence in which outside line groups will be accessed when in Automatic Line
Access mode. When a user dials the feature number for automatic line access (default=9/0) or
presses the Loop-CO button, an idle line is searched for in the programmed outside line group
order.
Selection
Outside line group number:
1 through 8 in desired order
Default
12345678
Programming
1.
Enter
103.
Display: 103 AUTO CO GRP
2.
Press
NEXT.
Display example: Access:12345678
3.
Enter the
outside line group numbers
in priority from top to bottom.
To delete the current entry, press
CLEAR.
To change the current entry, press
CLEAR
and enter the new order.
4.
Press
STORE.
5.
Press
END.
Conditions
• The system supports a maximum of eight outside line groups.
• Automatic Line Access feature works only if the Automatic Route Selection mode is turned
off in programme [312] ARS Mode.
Features Guide References
Line Preference – Outgoing (Idle Line / No Line / Prime Line)
Outside Line Access