EasyManua.ls Logo

Panasonic KX-TD816 - UCD Time Table

Panasonic KX-TD816
443 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.2 System Programming
General Programming 89
[123] UCD Time Table
Description
Assigns the queuing sequence in the Uniform Call Distribution (UCD) Time Table. The
queuing sequences are as follows:
S1
: Sends DISA (Direct Inward System Access) outgoing message 1.
S2
: Sends DISA outgoing message 2.
S3
: Sends DISA outgoing message 3.
S4
: Sends DISA outgoing message 4.
TR
: Transfers to the overflow extension.
RT
: Returns to the top of the sequence.
Blank
: Disconnects.
1T
: Timer – 16 seconds
2T
: Timer – 32 seconds
3T
: Timer – 48 seconds
4T
: Timer – 64 seconds
Selection
• Time Table number:
1 through 4
•
S1 / S2 / S3 / S4 / TR / RT / 1T / 2T / 3T / 4T / Blank
Default
All time tables – Not stored
Programming
1.
Enter
123
.
Display: 123 UCD T.TABLE
2.
Press
NEXT
.
Display: Table NO?
3.
Enter a
Time Table number
.
To enter Time Table number 1, you can also press
NEXT
.
Display example: 1:
4.
Keep pressing
SELECT
until the desired selection is displayed.
Display example: 1:S1
5.
Press .
6.
Repeat steps 4 and 5.
7.
Press
STORE
.
8.
Press
END
.