2.6 Utility
2.6.1 Utility—Diagnosis
Performs diagnostic tests on cards installed in the PBX, to identify the source of problems.
If any of the tests listed here returns the result "NG" ("No Good"), contact your dealer. Test results can be
saved as a TXT-format (text) file.
When testing
is complete, any cards that were set to OUS status must be returned to INS status if they are to
be used again.
Card Test
Tests the relevant functions of a card to ensure that it is operating correctly. The tests carried out vary according
to the type of card being tested.
The tests that are performed on each card are as follows:
Test Type Available Cards
Local loop back diagnosis DHLC, DLC, SLC8, SLC16, MSLC16, ESLC16, EMSLC16,
CSLC16, ECSLC24, CSIF, LCOT,
ELCOT, T1, E1, BRI, PRI, OPB,
E&M, DID, IP-EXT
Card CT Bus diagnosis
(KX-TDE100/KX-TDE200 only)
DHLC, DLC, SLC8, SLC16, MSLC16, CSLC16, CSIF, LCOT, T1,
E1, BRI, PRI, OPB
, E&M, DID, IP-EXT
DTMF Receive test port DHLC, SLC8, SLC16
, MSLC16, ESLC16, EMSLC16, CSLC16,
ECSLC24, E&M, DID
PT loop back diagnosis DHLC, DLC
DSP DTMF generator/receiver
diagnosis
T1, E1
DSP DTMF receiver diagnosis T1, E1
Framer IC alarm signal detection
diagnosis
T1, E1, PRI
Framer IC error detection diagnosis T1, E1, PRI
CS-INF loop back diagnosis CSIF
Super frame synchronization
diagnosis
CSIF
Caller ID card loop back diagnosis LCOT, ELCOT
Extension mode setting test BRI
IP-GW H.323 call simulate diagnosis IP-GW4, IP-GW16
LAN loop back diagnosis IP-GW4
To perform a card test
1. From the Utility menu, select Diagnosis.
2. Click on the Status cell of the card to be tested, and set it to "OUS".
64 PC Programming Manual
2.6.1 Utility—Diagnosis