Value Range
UDP
TCP
Default Value UDP
Configuration File Reference SIP_TRANSPORT_n (Page 228)
4.5.2.9 Timer Settings
T1 Timer
Description Selects the default interval, in milliseconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
250
500
1000
2000
4000
Default Value 500
Configuration File Reference SIP_TIMER_T1_n (Page 218)
T2 Timer
Description Selects the maximum interval, in seconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
2
4
8
16
32
Default Value 4
Configuration File Reference SIP_TIMER_T2_n (Page 219)
Timer B
Description Specifies the value of SIP timer B (INVITE transaction timeout timer),
in milliseconds. For details, refer to RFC 3261.
Value Range 250–64000
Default Value 32000
Configuration File Reference SIP_TIMER_B_n (Page 230)
98 Administrator Guide Document Version 2011-06