2-98
(8) Alarm Display
alarm
No.
Alarm Content
Latched
time
*1
A0 Overload protection Load factor is 85% or more the protection level.
WRVRU
A1
Over-regeneration
alarm
Regenerative load factor is 85% or more the
protection level.
VRU
A2 Battery alarm Battery voltage is 3.2 V or lower.
)L[HGDW
A3 Fan alarm Fan has stopped for 1 sec.
WRVRU
A4
Encoder communication
alarm
The number of successive encoder communication
HUURUVH[FHHGVWKHVSHFLÀHGYDOXH
WRVRU
A5 Encoder overheat alarm The encoder detects overheat alarm.
WRVRU
A6
Oscillation detection
alarm
Oscillation or vibration is detected.
WRVRU
A7 Lifetime detection alarm Life expectancy of capacitor or fan is short.
)L[HGDW
A8
External scale error
alarm
The external scale detects the alarm.
WRVRU
A9
External scale
communication alarm
The number of successive external scale
FRPPXQLFDWLRQHUURUVH[FHHGVWKHVSHFLÀHGYDOXH
WRVRU
*1 Alarms can be cleared by using the alarm clear. Because the all existing alarms are kept cleared while the alarm
FOHDULQSXW$&/5LVNHSW21EHVXUHWRWXUQLW2))GXULQJQRUPDORSHUDWLRQ(LWKHUVRUFDQEHVHOHFWHG
by using user parameter.
([FHSWLRQ%DWWHU\DODUPLVÀ[HGDWEHFDXVHLWLVODWFKHGE\WKHHQFRGHU
%HFDXVHWKHHQGRIOLIHDODUPPHDQVWKDWWKHOLIHH[SHFWDQF\FDQQRWEHH[WHQGHGWKHDODUPLVVHWDW
......No alarm occurred
......High priority alarm
Alarm number
7RGLVSOD\WKHDODUPRFFXUUHQFHFRQGLWLRQSUHVVRUEXWWRQ
15. How to Use the Front Panel
Monitor Mode (EXECUTION display)