EasyManua.ls Logo

Panasonic MINAS A5 Series - Page 409

Panasonic MINAS A5 Series
477 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-59
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
7
5.
Motor Characteristics
(
S-T
Characteristics
)
Supplement
MSME series :
without
brake
without
brake
* Continuous torque vs. ambient temp. * Continuous torque vs. ambient temp.
* Continuous torque vs. ambient temp. * Continuous torque vs. ambient temp.
MSME series
(
200W
)
* These are subject to change. Contact us when you use these values for your machine design.
MSME021 * 1 *
Input voltage to driver: AC100V
(Dotted line represents torque at 10% less voltage.)
MSME022 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
MSME022 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
MSME021 * 1 *
Input voltage to driver: AC100V
(Dotted line represents torque at 10% less voltage.)
Without oil seal With oil seal
torque
[N·m]
ratio vs. rated torque
[%]
speed [r/min] ambient temp. [°C]
50
100
torque
[N·m]
speed [r/min]
100203040
ratio vs. rated torque
[%]
with brake
ambient temp. [°C]
50
70
100
80
100203040
torque
[N·m]
ratio vs. rated torque
[%]
speed [r/min] ambient temp. [°C]
50
100
torque
[N·m]
speed [r/min]
100203040
ratio vs. rated torque
[%]
with brake
ambient temp. [°C]
50
70
100
80
100203040
Peak running range
Continuous running range
2.0
(0.8)
(0.32)
(2600) (3100)
1.0
0
1000 2000 3000 4000 5000 6000
Peak running range
Continuous running range
2.0
(0.8)
(0.32)
(2600) (3100)
1.0
0
1000 2000 3000 4000 5000 6000
(0.32)
Peak running range
Continuous running range
2.0
(1.3)
(1.1)
(4600)
1.0
0
1000 2000 3000 4000 5000 6000
(0.32)
Peak running range
Continuous running range
2.0
(1.3)
(1.1)
(4600)
1.0
0
1000 2000 3000 4000 5000 6000
:KHQ\RXORZHUWKHWRUTXHOLPLWVHWXS3DQG
running range at high speed might be lowered as well.
torque
speed
Continuous running range
Running range (Torque limit setup : 300%)
Running range (Torque limit setup : 200%)
Running range (Torque limit setup : 100%)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com