No. SX-DSV02472 -126-
8-3-2 Return timing from safety state
Photocoupler is
OFF.
Photocoupler is ON.
Photocoupler is OFF.
(Servo-OFF command)
Once the servo on
command is
input, the
operation
proceeds in
synchronous with
normal servo
on/off timing.
(Refer to
9-2
“Timing Chart”)
Not-energized
Max 6ms
Photocoupler is
ON. (Ready)
Photocoupler is OFF. (Alarm)
Photocoupler is OFF. (Not ready)
Photocoupler is OFF. (Break engage)
Photocoupler is OFF
.
Photocoupler is ON.
Photocoupler is ON.
(Not alarm)
Released/engaged *2
Servo-OFF
Released/engaged
*3
Generated alarm
Safety input 1
Safety input 2
Servo-ON input
SRV-ON*1
External brake
release output
(BRK-OFF)
Motor energization
Servo-Ready output
S-RDY
Servo-Alarm output
ALM
Servo-Clear intput
A-CLR*1
Dynamic brake
EDM output
output coupler
ON
Photocoupler is OFF.
Photocoupler is
ON.
(Servo-ON command)
Max
2ms
*1 Photocouplers for safety input 1 and 2 should be turned on again with servo-on input turned off. Otherwise, alarm
occurs, and should be cleared.
Alarm clear should be performed after the safety input 1 and 2 have been turned back to on. Otherwise, alarm occurs.
*2 This is an alarm condition and the dynamic brake operates according to Pr 5.10 (Sequence at alarm).
*3 This is normal servo-off condition and the dynamic brake operates according to Pr 5.06 (Sequence at Servo-Off).
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation