No. SX-DSV02472 -137-
Class 4: I/O monitor setting
Class No. Title Unit Range
Size
[byte]
Function / Contents Attribute
control
Reference
Set up function and logic of SI1.
Set up function and logic of SI2.
Set up function and logic of SI3.
Set up function and logic of SI4.
Set up function and logic of SI5.
Set up function and logic of SI6.
Set up function and logic of SI7.
Set up function and logic of SI8.
Set up SO1 function allocation.
Set up SO2 function allocation.
Set up SO3 function allocation.
16 Type of analog monitor 1
—
0–24 2
Select the type of monitor for analog
monitor 1.
A All 3-4
17
Analog monitor 1 output
gain
—
0–214748364 4
Set up the output gain of analog
monitor 1.
A All 3-4
18 Type of analog monitor 2
—
0–24 2
Select the type of monitor for analog
monitor 2.
A All 3-4
19 Analog monitor 2 output gain
—
0–214748364 4
Set up the output gain of analog
monitor 2.
A All 3-4
21 Analog monitor output setup
—
0–2 2
Select output voltage format of the
analog monitor.
A All 3-4
31
Positioning complete
(In-position) range
pulse 0–262144 4
Set up allowable the number of pulses
for positioning complete signal (INP).
A
4-2-4
32
Positioning complete
(In-position) output setup
- 0–4 2
Set up the condition for positioning
complete output.
A
4-2-4
33 INP hold time ms 0–30000 2 Set up the hold time A
4-2-4
34 Zero-speed r/min 10–20000 2
Set up threshold for zero speed (ZSP)
detection.
A All 2-4-2
35 Speed coincidence range r/min 10–20000 2
Set up threshold for detection of
speed coincident (V-COIN), by
detecting the difference between the
speed command and actual speed.
A
Velocity,
Torque
4-3-2
36 At-speed (Speed arrival) r/min 10–20000 2
Set the detection timing of the speed
arrival output (AT-SPEED).
A
4-3-1
37
Mechanical brake action at
stalling setup
ms 0–10000 2
Set up mechanical brake operating
time at stalling.
Set resolution in unit of 2 ms. For
example, when setting value = 11,
B All 9-2-2
38
Mechanical brake action at
running setup
ms 0–10000 2
Set up mechanical brake operating
time at running.
Set resolution in unit of 2 ms. For
example, when setting value = 11,
B All
9-2-3
9-2-4
39 Brake release speed setup r/min 30–3000 2
Set up the speed timing of brake
output checking during operation.
B All
40 Selection of warning output 1
—
0–14 2
Select the type of warning issued as
the warning output 1.
A All 7-3
41 Selection of warning output 2
—
0–14 2
Select the type of warning issued as
the warning output 2.
A All 7-3
42
Positioning complete
(In-position) range 2
pulse 0–262144 4
Set up acceptable the number of
pulses for positioning complete signal
A
Position
Full-closed
4-2-4
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation