No. SX-DSV02472 -137-
Class 4: I/O monitor setting
Class No. Title Unit Range
Size
[byte]
Function / Contents Attribute
Related
control
mode
Reference
4
00
SI1 input selection
0–00FFFFFFh
4
Set up function and logic of SI1.
C
All
2-4-1
01
SI2 input selection
0–00FFFFFFh
4
Set up function and logic of SI2.
C
All
2-4-1
02
SI3 input selection
0–00FFFFFFh
4
Set up function and logic of SI3.
C
All
2-4-1
03
SI4 input selection
0–00FFFFFFh
4
Set up function and logic of SI4.
C
All
2-4-1
04
SI5 input selection
0–00FFFFFFh
4
Set up function and logic of SI5.
C
All
2-4-1
05
SI6 input selection
0–00FFFFFFh
4
Set up function and logic of SI6.
C
All
2-4-1
06
SI7 input selection
0–00FFFFFFh
4
Set up function and logic of SI7.
C
All
2-4-1
07
SI8 input selection
0–00FFFFFFh
4
Set up function and logic of SI8.
C
All
2-4-1
10
SO1 output selection
0–00FFFFFFh
4
Set up SO1 function allocation.
C
All
2-4-1
11
SO2 output selection
0–00FFFFFFh
4
Set up SO2 function allocation.
C
All
2-4-1
12
SO3 output selection
0–00FFFFFFh
4
Set up SO3 function allocation.
C
All
2-4-1
16 Type of analog monitor 1
0–24 2
Select the type of monitor for analog
monitor 1.
A All 3-4
17
Analog monitor 1 output
gain
0–214748364 4
Set up the output gain of analog
monitor 1.
A All 3-4
18 Type of analog monitor 2
0–24 2
Select the type of monitor for analog
monitor 2.
A All 3-4
19 Analog monitor 2 output gain
0–214748364 4
Set up the output gain of analog
monitor 2.
A All 3-4
21 Analog monitor output setup
0–2 2
Select output voltage format of the
analog monitor.
A All 3-4
22
For manufacturer’s use
2
Permanently set at 0.
23
For manufacturer’s use
2
Permanently set at 0.
24
For manufacturer’s use
2
Permanently set at 0.
31
Positioning complete
(In-position) range
pulse 0–262144 4
Set up allowable the number of pulses
for positioning complete signal (INP).
A
Position,
Full-closed
4-2-4
32
Positioning complete
(In-position) output setup
- 0–4 2
Set up the condition for positioning
complete output.
A
Position,
Full-closed
4-2-4
33 INP hold time ms 0–30000 2 Set up the hold time A
Position,
Full-closed
4-2-4
34 Zero-speed r/min 1020000 2
Set up threshold for zero speed (ZSP)
detection.
A All 2-4-2
35 Speed coincidence range r/min 1020000 2
Set up threshold for detection of
speed coincident (V-COIN), by
detecting the difference between the
speed command and actual speed.
A
Velocity,
Torque
4-3-2
36 At-speed (Speed arrival) r/min 1020000 2
Set the detection timing of the speed
arrival output (AT-SPEED).
A
Velocity,
Torque
4-3-1
37
Mechanical brake action at
stalling setup
ms 0–10000 2
Set up mechanical brake operating
time at stalling.
Set resolution in unit of 2 ms. For
example, when setting value = 11,
processed in 12 ms.
B All 9-2-2
38
Mechanical brake action at
running setup
ms 0–10000 2
Set up mechanical brake operating
time at running.
Set resolution in unit of 2 ms. For
example, when setting value = 11,
processed in 12 ms.
B All
9-2-3
9-2-4
39 Brake release speed setup r/min 303000 2
Set up the speed timing of brake
output checking during operation.
B All
9-2-3
9-2-4
40 Selection of warning output 1
0–14 2
Select the type of warning issued as
the warning output 1.
A All 7-3
41 Selection of warning output 2
0–14 2
Select the type of warning issued as
the warning output 2.
A All 7-3
42
Positioning complete
(In-position) range 2
pulse 0–262144 4
Set up acceptable the number of
pulses for positioning complete signal
2 (INP2).
A
Position
Full-closed
4-2-4
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation

Table of Contents