EasyManua.ls Logo

Panasonic MINAS A6 Multi Series - Page 251

Panasonic MINAS A6 Multi Series
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.1List of parameters
9-7
No.
Title
Unit
Range
Size
[byte]
Function/Contents
Attribute
Related
control
mode
Reference
12
4th notch depth
selection
-
0 to 99
2
Set the notch depth of 4th
resonance suppression notch filter.
Automatically set when the adaptive
notch is enabled.
B
All
5.1.2
5.2.6
13
Selection of
damping filter
switching
-
0 to 6
2
Select the filters to be used for
damping control.
B
Position,
Full-closed
5.2.7
14
1st damping
frequency
0.1 Hz
0 to 3000
2
You can set up the 1st damping
frequency of the damping control
which suppresses vibration at the
load edge.
Setting value of 5 (= 0.5 Hz) or
higher is valid.
B
Position,
Full-closed
5.2.7
15
1st damping filter
setup
0.1 Hz
0 to 1500
2
Fine tune the 1st filter damping
control.
Decrease the setting value to avoid
torque saturation or increase the
value to improve the response.
B
Position,
Full-closed
5.2.7
16
2nd damping
frequency
0.1 Hz
0 to 3000
2
You can set up the 2nd damping
frequency of the damping control
which suppresses vibration at the
load edge. Setting value of 5 (= 0.5
Hz) or higher is valid.
B
Position,
Full-closed
5.2.7
17
2nd damping filter
setup
0.1 Hz
0 to 1500
2
Fine tune the 2nd filter damping
control.
Decrease the setting value to avoid
torque saturation or increase the
value to improve the response.
B
Position,
Full-closed
5.2.7
18
3rd damping
frequency
0.1 Hz
0 to 3000
2
You can set up the 3rd damping
frequency of the damping control
which suppresses vibration at the
load edge. Setting value of 5 (= 0.5
Hz) or higher is valid.
B
Position,
Full-closed
5.2.7
19
3rd damping filter
setup
0.1 Hz
0 to 1500
2
Fine tune the 3rd filter damping
control.
Decrease the setting value to avoid
torque saturation or increase the
value to improve the response.
B
Position,
Full-closed
5.2.7
20
4th damping
frequency
0.1 Hz
0 to 3000
2
You can set up the 4th damping
frequency of the damping control
which suppresses vibration at the
load edge. Setting value of 5 (= 0.5
Hz) or higher is valid.
B
Position,
Full-closed
5.2.7
21
4th damping filter
setup
0.1 Hz
0 to 1500
2
Fine tune the 4th filter damping
control.
Decrease the setting value to avoid
torque saturation or increase the
value to improve the response.
B
Position,
Full-closed
5.2.7
(To be continued)

Table of Contents

Related product manuals