Warning latch state
setup
Determine whether to latch warning
state.
General warning and Extended
warning can be specified.
bit 0: Extended warning
Real time auto
tuning estimation
speed
Set up the load characteristics
estimation speed with the Real-time
auto tuning being valid.
Real time auto
tuning custom setup
Set up details of Real-time auto
tuning customize mode.
Hybrid vibration
suppression gain
Set up the hybrid vibration
suppression gain for full-closed
controlling.
Hybrid vibration
suppression filter
Set up the time constant of the
hybrid vibration suppression filter for
full-closed controlling.
Dynamic brake
operation input
setup
Set enable or disable dynamic brake
(DB) operation input by I/O.
0: Disabled
1: Enabled
This function is available only when
the main power is turned off.
Oscillation detecting
level
Set up the oscillation detecting level.
Upon detection of a torque vibration
whose level is higher than this setup
value, the oscillation detection alarm
will be issued.
If set to 0, oscillation detection
warning is disabled.
Set up the alarm detection mask.
Placing 1 to the corresponding bit
position disables detection of the
alarm condition.
Specifies the damping depth of the
1st damping function.
2-stage torque filter
time constant
Specifies the filter time constant for
the torque command. The filter is
disabled if the setting value is 0.
This setting remains valid
irrespective of gain selection state.
2-stage torque filter
attenuation term
Specifies the attenuation term of the
2-stage torque filter.