9.1List of parameters
9-25
Set the damping depth for the 3rd
damping function.
Set the damping depth for the 4th
damping function.
Set the filter time constant for load
estimation.
Position,
Velocity,
Full-closed
Torque
compensation
frequency 1
Set the filter frequency 1 for speed
control output.
Position,
Velocity,
Full-closed
Torque
compensation
frequency 2
Set the filter frequency 2 for speed
control output.
Position,
Velocity,
Full-closed
Set the number of times regarding
load estimation.
Position,
Velocity,
Full-closed
Absolute encoder
multi-turn data
upper-limit value
Set the upper-limit value for
absolute encoder multi-turn data
when Pr0.15 is set to 4.
If multi-turn data exceeds the set
value, the multi-turn data changes to
0 instead of the set value.
When the multi-turn data falls below
0, multi-turn data will change to the
set value.
When set to Pr0.15 = 0 or
2(absolute mode), the upper limit of
the absolute rotation data becomes
65535, regardless of this setting.
This setting will become invalid
when Pr0.15 is set to 1 or 3.
Over-load warning
detection level
Sets the threshold value for
detecting the warning as the
overload load factor increases.
Sets with the overload load factor.
If 0 is set, overload warning
detection is performed under
conventional conditions (85% of
overload protection level).
In addition, if other than "Pr6.96 <=
Pr6.95 < (Overload level)" is set,
overload warning detection is
performed under conventional
conditions (85% of overload level).