9.1List of parameters
9-31
Maximum
continuation
communication
error
Set up the maximum of times of
continuation communication error
occurrence.
Err80.7 detection threshold
An ESM state after Init->PreOP
changes, When either Port0 or Port1
carries out this parameter setup time
progress in the state (Port which is
Lost link removes from an Init->PreOP
changes time) where it was set to Lost
link, Err85.2 "Lost link detection
unusual protection" occurs.
When 0 is set up, detection of Err85.2
"Lost link detection unusual
protection" is disabled.
-2147483648
to
2147483647
The software versions 1 and 2 of a
product are displayed.
Reserved (Permanently
set at 0)
Software version 1 (in
hexadecimal three-digit
notation)
Reserved (Permanently
set at 0)
Software version 2 (in
hexadecimal three-digit
notation)
For example, in the case of Software
version 1: 1.23 and Software version
2: 4.56, the value of this parameter will
be 01230456h (19072086).
Communication
function extended
setup 5
For manufacturer’s use
All bits permanently set at 0.
Power supply module contactor
output switching
0: Use EX-OUT1 with
general-purpose output 1
1: EX-OUT1 is used as the
contactor output (MC-OUT).
* This setting is valid only for the
Axis A parameter of the driver
module whose module
communication node address is
1.
For manufacturer’s use
All bits permanently set at
0.