5.1Automatic adjusting function
5-15
Real-time auto-tuning function sets the following parameters to the fixed value.
Relevant parameters
1st filter of velocity
detection
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 0.
2nd filter of velocity
detection
Velocity feed forward
gain
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 1000 (100%).
Velocity feed forward
filter
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 0 (invalid).
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 1000 (100%).
Torque feed forward
filter
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 0 (invalid).
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to bit4=1.
Adjust/Torque
command attenuation
term
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 15.
When Pr0.02=6, set the tenths digit to 1 and maintain the
unit digit.
The Real-time auto tuning function sets the following parameters as the gain is switched.
Relevant parameters
Sets to 1 if the current setting is not maintained (Pr0.02=1
to 4).
Mode of position
control switching
For the standard response mode (Pr0.02=1), set the
parameter to 0.
For high response mode 1 to 3 (Pr0.02=2 to 4), set the
parameter to 7.
Delay time of position
control switching
Sets to 10 if the current setting is not maintained
(Pr0.02=1 to 4).
Level of position
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Hysteresis at position
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Position gain
switching time
Sets to 10 if the current setting is not maintained
(Pr0.02=1 to 4).
Mode of velocity
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Delay time of velocity
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Level of velocity
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Hysteresis at velocity
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Mode of torque control
switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Delay time of torque
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Level of torque control
switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
Hysteresis at torque
control switching
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).