2-103
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
4) Clearing of Absolute Encoder
You can clear the multi-turn data of the absolute encoder.
Clearing of
absolute encoder
completes
Error occurs
(
When non-applicable
)
encoder is connected
Clearing of absolute encoder starts
Clearing
finishes
• Press to call for
EXECUTION display.
(SET button)
SELECTION display
EXECUTION display
“ ” increases while keep
pressing (for approx. 5sec)
as the left fig. shows.
Keep pressing until the display changes to
when you execute Clearing of Absolute Encoder.
Note
After clearing of absolute encoder nishes, return to SELECTION display, referring to struc-
ture of each mode (P.2-76).
14. How to Use the Front Panel
Auxiliary Function Mode (EXECUTION display)