4. Inputs and outputs on connector X4
Input Signal and Pin No.
Function allocatable to control input
Title of
signal
Servo-ON input
Related
control mode
P S T F
Symbol
SRV-ON
Default assignment
29 (SI6)
I/F circuit
SI P.3-33
This signal turns on/off the servo (motor).
Title of
signal
Positive direction over-travel inhibition input
Related
control mode
P S T F
Symbol
POT
Default assignment
9 (SI2)
I/F circuit
SI P.3-33
Positive direction over-travel inhibit input.
The operation with this input turned ON is set up in Pr5.04 “Setup of over-travel inhibit
input”.
When using this input, set Pr5.04 “Setup of over-travel inhibit input” to a value other than 1
so that the input is OFF when the moving portion of the machine exceeds this signal range
toward positive direction.
Title of
signal
Negative direction over-travel inhibition input
Related
control mode
P S T F
Symbol
NOT
Default assignment
8 (SI1)
I/F circuit
SI P.3-33
Negative direction over-travel inhibit input.
The operation with this input turned ON is set up in Pr5.04 “Setup of over-travel inhibit
input”.
When using this function, set Pr5.04 “Setup of over-travel inhibit input” to a value other
than 1 so that the input is OFF when the moving portion of the machine exceeds this signal
range toward negative direction.
Title of
signal
Deviation counter clear input
Related
control mode
P S T F
Symbol
CL
Default assignment
30 (SI7)
I/F circuit
SI P.3-33
Caution
• Clears the positional deviation counter.
Default setup clears the counter at the rising edge of the clear input, To change the setup,
modify it in the Pr5.17 “Counter clear input mode”.
<Signal width and clear timing>
Pr5.17 CL signal width Deviation clear timing
1 500 μs or more
Continually clear the counter while the deviation counter
clear input is ON.
*
1
2
1 ms or more
3 100 μs or more
Only once clear the counter at OFF to ON edge of the
deviation counter clear input signal.
*
1
4 1 ms or more
*
1 Deviation counter clear input ON/OFF = input photocoupler ON/OFF
This function can be assigned to only SI7. Allocation of this function to any other pin will
cause an error.
Related page
• P.4-52, 57 “Details of Parameter”