•Aparameterisdesignatedasfollows:
•ForparameterswhichNo.haveasuffixof“
*
”,changedcontentswillbevalidated
whenyouturnonthecontrolpower.
•P.3-32...“InputsandoutputsonconnectorX4”
Default: [ ]
Pr5.17
Counter clear input mode
Range Unit Default
Related
control mode
0 to 4 — 3 P F
Note
You can set up the clearing conditions of the counter clear input signal.
Setup value Clear condition
0 Invalid
1 Clearatalevel(noreadinglter)
2 Clearatalevel(withreadinglter)
[3] Clearatanedge(noreadinglter)
4 Clearatanedge(withreadinglter)
Forsignalwidth/timingrequiringthedeviationcounterinput,refertoP.3-40.
Pr5.18
Invalidation of command pulse inhibit
input
Range Unit Default
Related
control mode
0 to 1 — 1 P F
Select command pulse inhibit input enable/disable.
Setup value INH input
0 Valid
[1] Invalid
Pr5.19
*
Command pulse inhibit input reading
setup
Range Unit Default
Related
control mode
0 to 5 — 0 P F
Select command pulse inhibit input enable/disable signal reading period. When the status of
severalsignalsreadduringthepredeterminedreadingperiodaresame,updatethesignalstatus.
Setup value Signal reading period
[0] 0.250 ms to 3 times continuous
1 0.500 ms to 3 times continuous
2 1.0 ms to 3 times continuous
3 2.0 ms 3 times continuous
4 0.250 ms to read 1 time
5 0.250 ms to 2 times continuous
Longer reading period protects against operation error due to noise but decreases response
to input signal.
1. Details of parameter
[Class 5] Enhancing setting