2-10
2
Preparation
2.
System Conguration and Wiring
Driver and List of Applicable Peripheral Equipments
List of Peripheral Equipments
Driver Voltage
*1
Rated
output
Required
Power
at the
(
rated load
)
Circuit
breaker
rated
(
current
)
Noise
lter
(
Single phase
/
3-phase
)
Surge
absorber
(
Single phase
/
3-phase
)
Noise
lter for
signal
Rated operating
current of magnetic
contactor Contact
(
conguration
)
*
2
MADL□□□□□
Single phase,
100 V
50 W to 100 W
approx.
0.4 kVA
10 A
DV0P4170 DV0P4190
DV0P1460
20 A
(3P+1a)
Single/3-phase,
200 V
50 W to 200 W
approx.
0.5 kVA
DV0P4170
/
DV0PM20042
DV0P4190
/
DV0P1450
MBDL□□□□□
Single
100 V 200 W
approx.
0.5 kVA
DV0P4170 DV0P4190
Single/3-phase,
200 V
400 W
approx.
0.9 kVA
DV0P4170
/
DV0PM20042
DV0P4190
/
DV0P1450
MCDL□□□□□
Single
100 V 400 W
approx.
0.9 kVA
15 A
DV0PM20042
DV0P4190
Single/3-phase,
200 V
750 W
approx.
1.3 kVA
DV0P4190
/
DV0P1450
MDDL□□□□□ 3-phase,
200 V
1.0 kW
approx.
1.8 kVA
20 A
DV0P4220
30 A
(3P+1a)
0.9 kW
approx.
1.8 kVA
1.0 kW
approx.
1.8 kVA
1.5 kW
approx.
2.3 kVA
MEDL□□□□□ 3-phase, 200 V
2.0 kW
approx.
3.3 kVA
30 A
DV0PM20043
DV0P1450
DV0P1460
RJ8035
Recommended
(
component
)
*
4
60 A
(3P+1a)
2.5 kW
approx.
3.8 kVA
MFDL□□□□□ 3-phase, 200 V
2.0 kW
approx.
3.8 kVA
50 A
DV0P3410
DV0P1450
DV0P1460
RJ8035
Recommended
(
component
)
*
4
60 A
(3P+1a)
3.0 kW
approx.
4.5 kVA
4.0 kW
approx.
6.0 kVA
100 A
(3P+1a)
4.5 kW
approx.
6.8 kVA
5.0 kW
approx.
7.5 kVA
List of Applicable diameter cables
Driver
Voltage
*1
Rated
output
Required
Power
at the
(
rated load
)
Diameter
and
withstand
voltage of
main circuit
cable
Crimp
terminal
for main
circuit
terminal
block
Diameter
and
withstand
voltage
of control
power
supply cable
Crimp
terminal
for control
power
supply
terminal
block
Diameter
and
withstand
voltage of
motor cable
*4
Diameter
and
withstand
voltage of
brake cable
MADL□□□□□
Single phase,
100 V
50 W to 100 W
approx.
0.4 kVA
0.75 mm
2
/
AWG18
600 VAC
or more
Connection
to exclusive
connector
0 75 mm
2
/
AWG18
600 VAC
or more
Connection
to exclusive
connector
0.75 mm
2
/
AWG18
600 VAC
or more
0 28 mm
2
/
AWG22
to
0 75 mm
2
/
AWG18
100 VAC
or more
Single/3-phase,
200 V
50 W to 200 W
approx.
0.5 kVA
MBDL□□□□□
Single phase,
100 V
200 W
approx.
0.5 kVA
Single/3-phase,
200 V
400 W
approx.
0.9 kVA
MCDL□□□□□
Single phase,
100 V
400 W
approx.
0.9 kVA
Single/3-phase,
200 V
750 W
approx.
1.8 kVA
MDDL□□□□□
Single/3-phase,
200 V
0.9 kW
approx.
2.3 kVA
2.0 mm
2
/
AWG14
600 VAC
or more
2.0 mm
2
/
AWG14
600 VAC
or more
0 75 mm
2
/
AWG18
100 VAC
or more
1.0 kW
approx.
2.4 kVA
1.5 kW
approx.
2.9 kVA
Related page
Noise lter...P.7-108 Surge absorber...P.7-110
Ferrite coil...P.7-111 Motor/brake connector...P.2-28
When use the external regenerative resistor of the option, use the cable with the same diameter as the
main circuit cable.
Note
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com