Loading...
– 18 –
How to Operate
C. PROGRAMMING MEMORY PADS
X Single stage heating
THE OVEN CAN NOT BE PROGRAMMED WHEN PROGRAM LOCK IS ACTIVATED! (see page 20)
DO NOT OPEN THE DOOR WHILE PROGRAMMING!
Example: To program cooking at DEFROST power for 1 minute into Memory pad “5”
PAD INSTRUCTION
DIGITAL DISPLAY WINDOW
1
Keep the door closed.
Digital Display Window must be blank or show “0”.
2
PROG
Press Program Entry Switch.
“PROG” will start to blink.
PROG
3
5
Press Memory pad you wish to program.
The selected pad number will appear and currently programmed
information will be indicated.
1
A
PROG
4
Press Power Level Selector pad four times.
The selected power level will be indicated, “PROG” and 1st Stage
Heating Indicator “1” will start to blink.
1
A
PROG
5
Set the desired heating time using Timer Dial.
The set heating time will appear.
Note: up to 15 min. on or , 60 min. on , or
1
A
PROG
6
PROG
Press Program Entry Switch again.
“PROG” and 1st Stage Heating Indicator “1” will stop blinking.
This means that you have completed programming.
1
A
PROG
• Three seconds later, Digital Display Window will go blank.
Note:
• Program the remaining Memory pads as desired by repeating steps 2-6 above.
When you want to select Memory Area B, press Memory Shift pad
A B
before selecting the desired Memory pad.