39
5. Watch out the fan motor cables go through the multiflow.
Remove the sealing material (putty).
Note: Keep sealing material for re-sealing the con-
nectors after replacement.
6. Remove the sealing material (putty) at left housing. Then
pink and white connector can be seen in one housing.
Black leaded wires are connected with fan motor. Discon-
nect the fan motor connectors.
7. Cut both the black lead wires which comes from white
and pink color connectors.
Replace the multiflow cover with new one, follow the
steps for fan motor cable connections which described at
next part. Then close the cover parts and fix the screws
respectively.