4.3. Fan Control
While compressor is running, evaporator fan is running.
When compressor stops and if damper motor is closed 2min run - 2 min stop operation starts and continue until compressor runs
or damper motor opens again.
If ambient temperature is ATC 22 °C or ATC 30 °C
While compressor is running, evaporator fan motor is running.
If PCC sensor is warmer than damper on set values damper must be on and fan motor must work continiously untill PCC sensor
reach to damper close set values.
If PCC sensor is colder than damper close set values damper must be off and if compressor is stopping fan also must be off.