3.2 OGM Recording – IP-PT
The manager extension (COS Setting) can record three kinds of greeting messages (OGM) as follows:
1. DISA message: Used to greet and guide callers.
2. Incoming Call Distribution Group message: Used to greet and guide callers to an ICD-G
3. Timed Reminder message: Used for a wake-up call message.
OGM recording can be accomplished via a Manager Extension using the sequence below
To Record
To Playback
On-hook.
Off-hook.
Enter 1.
1
Record
message.
Press STORE.
When the time limit passes,
it stops automatically.
The message
is played back.
Enter 36.
3 6
Enter OGM floating
extension number.
OGM floating
extension no.
Progress
Tone &
C.Tone
C.Tone
9
Enter 9 and
site ID (2 digits: 01–16).
site ID
To specify a site ID
(if necessary)
The message
is played back.
Off-hook.
On-hook.
2
Enter 36. Enter 2.
63
C.Tone
Enter OGM floating
extension number.
OGM floating
extension no.
9
Enter 9 and
site ID (2 digits: 01–16).
site ID
To specify a site ID
(if necessary)