Chapter 5Maintenance — Lamp/temperature/lter indicators
ENGLISH - 163
Temperature indicator <TEMP>
Indicator status Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status Warm-up status
Internal temperature is high
(warning).
Internal temperature is high
(standby status).
The cooling fan has
stopped.
Cause
f Did you turn on the power
when the temperature
was low (around 0 °C
(32 °F))?
f Is the air intake/exhaust port blocked?
f Is the room temperature high?
f Is the lter indicator <FILTER> lit?
Solution
f Wait at least 10 minutes in
the current status.
f Install the projector in a
location with the operating
environment temperature
between 0 °C (32 °F) and
45 °C (113 °F)
*1
.
f Remove any objects that are blocking the air intake/
exhaust port.
f Install the projector in a location with the operating
environment temperature between 0 °C (32 °F) and
45 °C (113 °F)
*1
.
f Do not use the projector at high altitudes of 2 700 m
(8 858') or higher above sea level.
f Clean or replace the air lter. (x page 164)
f Turn the <MAIN POWER>
switch to <OFF>
(x page 61), and
consult your dealer.
*1 When using the projector at high altitudes (between 1 400 m (4 593') and 2 700 m (8 858') above sea level), the operating environment temperature
should be between 0 °C (32 °F) and 40 °C (104°F).
Note
f If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
f If you use the projector with the following two settings, the light output may be reduced by approx. 20 % to protect the projector when the
operating environment temperature becomes 40 °C (104 °F) or higher (35 °C (95 °F) or higher when used at high altitude).
g When [LAMP SELECT] is set to [DUAL] from the menu
g When [LAMP POWER] is set to [NORMAL] from the menu
Filter indicator <FILTER>
Indicator status Lighting in red Blinking in red
Status
The lter is clogged.
The temperature inside or outside the projector is abnormally high.
The air lter case is not attached.
Cause f Is the air lter dirty?
f Is the air intake/exhaust port
blocked?
f Is the air lter case attached?
Solution
f Clean or replace the air lter.
(x page 164)
f Remove any objects that are
blocking the air intake/exhaust port.
f Attach the air lter case.
Note
f If the lter indicator <FILTER> is still lit or blinking after taking the measures, ask your dealer for repair.
f If the air lter case is not attached when the projector is switched on, the lter indicator <FILTER> blinks in red.