DIS-13
4. Unscrew the 17 screws and remove the Terminal Plate.
Unscrew the 5 screws and remove the A-P.C.Board.
 2.11. Removal of Ballast Block (B/Q-P.C.Board)
1. Remove the Lamp Cable Socket (two places) according to the steps 1 through 4 in the section 2.6. "Removal of
Analysis Block / Synthesis Block / Synthetic Mirror".
2. Unscrew the 2 screws and remove the Back Fan Case.
3. Unscrew the 2 screws and remove a Ballast Block in an upside after sliding to the direction of the arrow.
THEC084N
XYN3+F8FJ
XYN3+F8FJ
XTB3+8JFJ
XQN2+B5FJ
XYN26+C6FJ
Terminal Plate
XYN3+F8FJ
A-P.C.Board
XYC3+FG10FJK
Back Fan Case
Ballast Block
XYN3+F8FJ
Ballast Block