No. Abnormal Items Error
Display
Method of detection
1 CLOSE SW abnormal H16 Detect error during closing operation and
memorised
as an error.
2 REST SW abnormal F15 Under normal operation (Self-Diagnostic Mode
inclusive), this error occurs when the REST
SW
not detected within the specified time (5000
ms)
shall be memorised.
3 Transmission error between
CD servo LSI and micon
F26 Under normal operation (Self-Diagnostic Mode
inclusive), this error occurs when the
selection
CD and SENSE =’H’ is detected and SENSE =’
L
detected within a fail-safe time (20 ms) after
system
command transmission was sent.
9. Operation Checks and Main Component
Replacement Procedures
ATTENTION SERVICER”
Some chassis components maybe have sharp edges. Be careful when diassembling and
servicing.
1. This section describes procedures for checking the operation of
the major printed circuit boards and replacing the main
components.
2. For reassembly after operation checks or replacement, reverse
the respective procedures. / Special reassembly procedures are
described only when required.
3. Select items from the following index when checks or
replacement are required.
4. Refer the Parts No. on the page of Main component Replacement
Procedures, if necessary.
Content
- Checking Procedure for each major P.C.B.
1. ing for the Main, Panel, Tuner, Power & Cd Servo P.C.B
........................................................................... P.g. 8 ~ 11
- Main Component Replacement Procedures
1. Replacement of the Traverse Deck