1-1-15
11
Single-Type
1-1. Unit Specifications
Ducted Type S-125PE1R5B / U-125PZ2R8
INDOOR MODEL S–125PE1R5B
PANEL MODEL
OUTDOOR MODEL U-125PZ2R8
Branch pipe MODEL
Performance test condition ISO13253 / AS/NZS3823.1
Power supply
ø, Hz 1ø 50 Hz 3ø 50 Hz
V 230 V 240 V 400 V 415 V Min Max
C
O
O
L
I
N
G
Capacity
kW 12.5 12.5 3.2 13.5
BTU/h 42700 42700 10900 46100
Current A 1.82 1.84 5.20 4.95
Input power
W 410 430 3.380k 3.360k
TOTAL W 3.790k 3.790k 900 5.100k
Annual consumption TOTAL kWh *
4
1895
EER/ AEER/ STAR RATING TOTAL (W/W/-)
3.30/3.24/-
3.30 3.56 2.65
Power factor % 94 94
Noise indoor
dB-A (H/M/L) 49/47/45
Power Level dB 71/69/67
Noise outdoor
dB-A (H/L) 55/–
Power Level dB 70/–
H
E
A
T
I
N
G
Capacity
kW 12.5 12.5 3.3 15.0
BTU/h 42700 42700 11300 51200
Current A 1.82 1.84 4.15 4.00
Input power
W 410 430 2.715k 2.695k
TOTAL W 3.125k 3.125k 905 4.505k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
4.00/3.94/-
4.00 3.65 3.33
Power factor % 94 94
Noise indoor
dB-A (H/M/L) 49/47/45
Power Level dB 71/69/67
Noise outdoor
dB-A (H/L) 55/–
Power Level dB 70/–
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
Max Current (A) / Max Input power (W) 2.1/470 2.2/500 10.0/6500 10.0/6750
Starting current (A) / Comp output (W)
5.20/2.80k 4.95/2.80k
Network Impedance (ΩMAX.)
Fan motor output (Indoor/Outdoor) W 310 120
Moisture removal volume L/h(Pt/h) 7.9 (16.6)
External static pressure Pa 100 (MIN10 – MAX150)
Indoor
Air ow
Cooling m
3
/min (ft
3
/min) 50/46/36 (1766/1624/1271)
Heating m
3
/min (ft
3
/min) 50/46/36 (1766/1624/1271)
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min) 86.0 (3037)
Heating m
3
/min (ft
3
/min) 78.0 (2754)
Refrigerant type / amount
g
(oz) R32 2.98 k (105.1)
Product dimension
Height mm(inch) 430 (16–15/16) 996 (39- 7/32)
Width mm(inch)
1100(+100)
(
43–5/16(+3–15/16))
980 (38-37/64)
Depth mm(inch) 700 (27–9/16) 370 (14- 9/16)
Packing dimension
Height mm(inch) 515 1134 (44-41/64)
Width mm(inch) 1315 1095 (43-7/64)
Depth mm(inch) 812 529 (20-53/64)
Weight
(NET) k
g
(lb) 48 94 (207)
(GROSS) k
g
(lb) 56 102 (224)
Layers limit (actually) 6(7) 2(3)
Operation condition
Cool (DBT) 18˚C – 32˚C -10˚C – 43˚C
Heat (DBT) 16˚C – 30˚C -15˚C – 24˚C
MAX WORKING PRESSURE HP/LP MPa (bar) 4.15/2.55 (41.5/25.5)
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
Connecting method, Standard length m(ft) ared type, 5.0(16.4) ared type, 5.0(16.4)
Pipe length range m (ft) 5 ~ 50m (16.4 ~164.0)
Indoor unit & Outdoor unit height difference m (ft) 15m(OD located lower)/30m(OD located higher) (49.2/98.4)
Add gas amount
g
/m (oz/ft) 45
g
/m
(0.484)
Pipe length for additional gas m (ft) 30m (98.4)
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
SM830266-00_大洋州向けR32シングルTD&SM.indb 15 18/03/29 10:19:23