1-1-19
11
Single-Type
1-1. Unit Specifications
Ceiling Type S-71PT2E5B / U-71PZ2R5
INDOOR MODEL
S-71PT2E5B – –
PANEL MODEL
– – –
OUTDOOR MODEL
– U-71PZ2R5 –
Branch pipe MODEL
–
Performance test condition
ISO5151 / AS/NZS3823.1
Power supply
ø, Hz
1ø 50 Hz 1ø 50 Hz
V
– 230 V 240 V – 230 V 240 V Min Max
C
O
O
L
I
N
G
Capacity
kW
– 7.1 7.1 – – – 2.0 8.0
BTU/h
– 24200 24200 – – – 6800 27300
Current A
– 0.44 0.43 – 8.95 8.60 – –
Input power
W
– 55 55 – 1.875k 1.875k – –
TOTAL W
– – 1.930k 1.930k 300 2.550k
Annual consumption TOTAL kWh *
4
– – 965 – – –
EER/ AEER/ STAR RATING TOTAL (W/W/-)
– – – –
3.68/3.57/2.5
3.68 6.67 3.14
Power factor %
– – – – 91 91 – –
Noise indoor
dB-A (H/M/L)
39/35/31 – – –
Power Level dB
57/53/49 – – –
Noise outdoor
dB-A (H/L)
– 49/– – –
Power Level dB
– 67/– – –
H
E
A
T
I
N
G
Capacity
kW
– 7.1 7.1 – – – 1.8 8.6
BTU/h
– 24200 24200 – – – 6100 29300
Current A
– 0.44 0.43 – 7.55 7.25 – –
Input power
W
– 55 55 – 1.565k 1.565k – –
TOTAL W
– – 1.620k 1.620k 230 2.700k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
– – – –
4.38/4.23/3.5
4.38 7.83 3.19
Power factor %
– – – – 90 90 – –
Noise indoor
dB-A (H/M/L)
39/35/31 – – –
Power Level dB
57/53/49 – – –
Noise outdoor
dB-A (H/L)
– 49/– – –
Power Level dB
– 67/– – –
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
– –
Max Current (A) / Max Input power (W)
0.44/55 0.43/55
–
16.4/3.39k
16.4/3.54k
–
Starting current (A) / Comp output (W)
– – – 8.95/2.0k 8.60/2.0k –
Network Impedance (ΩMAX.)
– – –
Fan motor output (Indoor/Outdoor) W
74 60 –
Moisture removal volume L/h(Pt/h)
4.2 (8.8) – –
External static pressure Pa
– – –
Indoor
Air ow
Cooling m
3
/min (ft
3
/min)
21/18/15.5 (742/636/547) – – –
Heating m
3
/min (ft
3
/min)
21/18/15.5 (742/636/547) – – –
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min)
– 52 (1836) – –
Heating m
3
/min (ft
3
/min)
– 45 (1589) – –
Refrigerant type / amount
g
(oz)
–
R32 1.45 k (51.1)
–
Product dimension
Height mm(inch)
235 (9-1/4)
695 (27-23/64)
–
Width mm(inch)
1275 (50-3/16)
875 (34-29/64)
–
Depth mm(inch)
690 (27-5/32)
320 (12-38/64)
–
Packing dimension
Height mm(inch)
360
(14-11/64) 761 (29-61/64)
–
Width mm(inch)
1340
(52-3/4) 1049 (41-19/64)
–
Depth mm(inch)
820
(32-9/32) 460 (18-7/64)
–
Weight
(NET) k
g
(lb)
33 (73) 44 (97) –
(GROSS) k
g
(lb)
42 (93) 49 (108) –
Layers limit (actually)
9 (10) 3 (4) –
Operation condition
Cool (DBT) 18˚C – 32˚C -10˚C – 43˚C
–
Heat (DBT) 16˚C – 30˚C -15˚C – 24˚C
–
MAX WORKING PRESSURE HP/LP MPa (bar) 4.15/2.55 (41.5/25.5)
–
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
–
Connecting method, Standard length m(ft)
ared type, 5.0(16.4) ared type, 5.0(16.4) –
Pipe length range m (ft)
3 – 40m (9.8 – 131.2) –
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4) –
Add gas amount
g
/m (oz/ft)
35
g
/m
(0.376) –
Pipe length for additional gas m (ft)
30m (98.4) –
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
SM830266-00_大洋州向けR32シングルTD&SM.indb 19 18/03/29 10:19:24