15.7.2 60 x 60 Cassette (YA1E5 Series)
Air swing direction setting Manual
Mode Condition
Step 1 Step 2 Step 3 Step 4
Normal 20° 37° 53° 70°
Deice 10°
Hot start 10°
Heat removal control 20°
Heat
Thermostat OFF 20°
Normal 20° 37° 53° 70°
Dew control 37° 37° 45° 45°
Cool/Fan
Thermostat OFF 20° 37° 53° 70°
Normal 37°
Dew control 37° 37° 45° 45°
Dry
Thermostat OFF 20° 37° 53° 70°
Automatic mode judgment 20° 37° 53° 70°
Operation stop 0°
Air swing direction setting Automatic
Mode Condition
Zone A 70° 70° 70°
Zone B 20° ~ 70° 20° ~ 53° 42° ~ 70°
Indoor heat
exchanger
temperature
Zone C 20° 20° 20°
Deice 10°
Hot start 10°
Heat removal control 20°
Heat
Thermostat OFF 20°
Normal 20° ~ 70° 20° ~ 53° 42° ~ 70°
Dew control 34° ~ 45° 37° ~ 45° 42° ~ 45°
Cool/Fan
Thermostat OFF 20° ~ 70° 20° ~ 53° 42° ~ 70°
Normal 37°
Dew control 37° ~ 45° 37° ~ 45° 42° ~ 45°
Dry
Thermostat OFF 20° ~ 70° 20° ~ 53° 42° ~ 70°
Automatic mode judgment 20° 20° 20°
Operation stop 0°
• Heating automatic air swing control according indoor unit heat exchanger temperature.
60
o
C
57
o
C
Zone A
Zone B
Zone C
25
o
C
30
o
C
Indoor heat exchanger temperature